Dipfree

Voltage-dip compensation device for single phase

1 Dipfree.png

Compensate voltage-dip: Standard specification of compensating voltage-dip, interruption in 1 second.

Obtained S Mark, CE, TUV Certifications.

Dip compensation Counter and display.

Adjust time for Dip compensation (0.1 ~ 5.0 sec).

Set Dip compensation operation voltage (AC 170~190V, AC85~99V).

Set Dip compensation output voltage (AC200/210/220/230V, AC100/110/120V).

Off-line : Stand by when normal power is applied. Compensate only on accidents.

No battery : Low maintenance costs and free from disposing wastes, does not produce chemical GAS.

Power Capacitor charging : Long life span of at least 10 years.

Highly reliable : High-speed connection within 1msec.

Stability : Low heat generation and safe by operating in of f-line.

Strong resistance against high inrush current : Does not need 2~3 times larger size like UPS or CVT, respond to voltage-dip.

Easy installation with small size and light weight : Does not need Step-Up transformer or battery.

Deal for induction and low power factor load.

Semiconductor relay contact notifying Dip compensation (Optional : possible to use as an alarm).

Nontrip
M/C, Relay Controller : Nontrip

2 Nontrip.png

Nontrip provides economical solution for preventing Trip by Magnetic Contractor

caused by voltage-dip and Voltage-Sag.

It does not require battery thus free from separate maintenance and repairs.

 

Compatible with AC and AC/DC, M/C by embedding SMU(Super Magnetic Unit)

Possible to apply on national international M/C models

Minimized installation space by making it small and light

Socket Type allowing easy installation and maintenance

1 second compensation on voltage-dip

Self-diagnosis and indicate number of operations

Highly economical

National patent (Patent No 0267075)

S Safety Mark and CE International Certification

DSP

SMPS Controller : DSP

3 DSP.png

DSP is a preventative controller for voltage-dip for SMPS (Switching Module Power Supply) and it provide a solution for preventing Trip on SMPS caused by voltage-sag and dip.  It does not require separate maintenance since it does not require battery.

Exclusively for SMPS (Switching Module Power Supply)

19inch Rack Type

Compensation within 1 second on dip

Self-diagnosis and display number of operations

Highly economical

CE, TUV Certified Product

Model : CP3000 / CP1800

Compensation Capacity: 3,000VA / 1,800VA

Input voltage: 1ø 200Vac ~ 230Vac, 50/60Hz

Output voltage : 200Vdc ~ 230Vdc

Operation voltage : 185Vac ± 3V

Compensation time : 1,000msec

Applied load : Exclusively for SMPS

VDS

Voltage Dip Simulator : VDS

4 VDS.png

VDS is a Voltage Dip, Sag testing device and causes man-made voltage dip

to load and analyze endurance on voltage-dip that the load has

 

Test voltage dip with range up to -100%

User can set arbitrary voltage dip

User can set arbitrary time

Set artificial phase

Display setting and number of tests on LCD display

Set number of continuous repetitions

 

Model : VDS-2000 / VDS-3000

Load Capacity : 2,000VA / 3,000VA

Input voltage : 1ø 200Vac ~ 230Vac, 50/60Hz

Output voltage : 1ø 0Vac ~ 230Vac, 50/60Hz

Range of phase : 0°~ 360° (change by 10° unit)

Time range : 1msec ~ 9,999msec

Number for continuous repetitions : 1 ~ 100 times

Applied load : A single phase load within permissible capacity

AMTS

Bypass Switch : AMTS

5 AMTS.png

1. Function : Supply power to load uninterrupted, automatic/manual connection

2. Purpose : Maintain uninterrupted power supply during inspection on controller, maintaining controller

3. Specification : 25A, 40A

4. Model : AMTS-25, AMTS-40 (exclusively for DVC-5000-N2, DVC-2500-N1)